Explanation
Abort subroutine processing (VDI signal: Program level abort).
Not allowed if
1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy
Abort program
No. 18
Explanation
Activate single block (VDI signal: Activate single block).
Not allowed if
-
Remedy
-
No. 19
Explanation
Deactivation of single block (VDI signal: Activate single block).
Not allowed if
-
Remedy
-
No. 20
Explanation
Activate main run single block (OPI variable and VDI signal: Activate single block).
Not allowed if
-
Remedy
-
No. 21
Explanation
Activate decoding single block (OPI variable and VDI signal: Activate single
block).
Not allowed if
1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
− Wait until the preceding asynchronous subroutine is terminated or abort the pro-
Remedy
gram
− Abort program