Siemens SINUMERIK 840D sl Series Diagnostics Manual page 538

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Remedy:
RAM type = 1: Increase size of buffer memory ($MN_MM_USER_MEM_BUFFERED) or
the available space in the buffer memory, e.g. by unloading unused parts programs. Alter-
natively the ring buffer can be decreased via MD $MC_RESU_RING_BUFFER_SIZE.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
75609
Channel %1 RESU: POS axis not permitted, axis type %2, block no. %3
Parameters:
%1 = Channel number
%2 = Axis type
%3 = Block number
Definitions:
A geometry axis is traversed as positioning axis at active CC_RREPRE.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
In order to traverse a geometry axis as positioning axis, RESU must be switched off tem-
porarily (with CC_PREPRE(0) ) or completely. In order to make the internal axis state
change from the geometry axis as positioning axis after traversing, a block without travel-
ing motion must be programmed, if required: e.g. X=IC(0)
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75610
Channel %1 RESU: NC start currently not possible
Definitions:
While RESU is active, no NC START must be performed in certain situations. If NC
START is confirmed nevertheless, execution will be blocked and alarm 75610 will be dis-
played. This applies in the following situations:
On requesting return traveling: NC START is blocked when return traveling program
cc_resu.mpf has been created and selected.
After having triggered continuation under NC STOP condition: as long as the internally
started block search or the finally started Asup cc_resu_bs_asup.spf is running.
Reactions:
- Interface signals are set.
- Alarm display.
Remedy:
Wait for completion of the current internal procedure. Then delete the alarm with NC
START and continue
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
100001
Function %1 not yet implemented!
Parameters:
%1 = --
Definitions:
--
Remedy:
--
100002
MS DOS test version !
Definitions:
--
Remedy:
--
100003
Test version only !
Definitions:
--
Remedy:
--
100004
Function %1 not yet finally implemented!
2-538
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition