Overview of Alarms
108012
Zoom is empty
Definitions:
--
Remedy:
--
109000
New NCK address has been transferred to NCK
Definitions:
--
Remedy:
--
109001
No switchover: Switchover disable set in current PLC
Definitions:
MMC would like to go offline from this NCU.
The MMC switchover is disabled in the MMC PLC online interface in DB19.
(MMCx_SHIFT_LOCK = TRUE, x = 1,2)
Remedy:
--
109002
No switchover: Target PLC used, try again
Definitions:
MMC would like to go online to this NCU.
MMC has called the target PLC and is awaiting acknowledgement.
MMC bekommt keine Quittung, da die MMC-Parameter-Schnittstelle in DB19 von einem
anderen MMC belegt ist.
Remedy:
Repeat the operation at a later point in time, as the MMC parameter interface in DB19 is
only temporarily occupied.
109003
No switchover: Switchover disable set in target PLC
Definitions:
MMC would like to go online to this NCU.
The MMC switchover is disabled in the MMC PLC online interface in DB19.
(MMCx_SHIFT_LOCK = TRUE, x = 1,2)
Remedy:
The MMC switchover is disabled/enabled in the machine manufacutrer's PLC program.
Reference to the machine manufacturer's documentation.
109004
No switchover: PLC occupied by higher-priority HMIs
Definitions:
The MMC is attempting to switch to an NCU that is occupied by two higher-priority
MMC's.
Remedy:
Switch one of the two higher-priority MMC's to another NCU.
109005
No switchover: No HMI displaceable on target PLC
Definitions:
MMC would like to go online to this NCU.
At this NCU, two MMC's are online on which uninterruptable processes are active (e.g.:
data transfer between MMC and NCU).
Remedy:
Wait until at least one of the two MMC's can be displaced and repeat the switchover.
109006
No switchover: Selected channel invalid
Definitions:
At this NCU, the MMC was switched to a channel that does not exist there.
Remedy:
Set up the channel or adapt the parameterization of the NETNAMES.INI.
109007
Channel switchover running
Definitions:
The channel switchover has been initiated.
A different MMC may have to be displaced.
2-584
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition