Overview of Alarms
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
• For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
• For third-party motors: Check and, if necessary, refer to the motor data sheet to correct
MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current).
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
300786
Axis %1 drive %2 field weakening speed invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field
weakening) is less than or equal to zero.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
• For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
• For third-party motors: Check and, if necessary, refer to the motor data sheet to correct
MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weakening).
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
300787
Axis %1 drive %2 asynchronous mode: feedforward control gain out of range
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
If motor inertia and motor nominal torque have been selected unfavorably, the asynchro-
nous motor feedforward control gain is beyond the range of the internal number format.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
2-886
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition