Siemens SINUMERIK 840D sl Series Diagnostics Manual page 920

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Remedy:
Enter a smaller value for the D component of the force controller MD 5246:
FORCECTRL_DIFF_TIME.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
310764
Axis %1 drive %2 controlled system gain for force controller is less than or equal to
zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The controlled system gain for the force controller in drive MD 5240
FORCECONTROLLED_SYSTEM_GAIN is less than or equal to zero.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Set a valid controlled system gain in drive MD 5240
FORCECONTROLLED_SYSTEM_GAIN (see model data calculations).
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
310771
Axis %1 drive %2 gain in fine area of valve characteristic is less than or equal to
zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The gradient in the fine area of the valve characteristic is less than or equal to zero.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
The gradient in the fine area is calculated as follows:
• Positive quadrant: (MD 5464 - MD 5480) / (MD 5465 -5481)
• Negative quadrant: (MD 5467 - MD 5483) / (MD 5468 - 5484)
Enter a valid combination in the above drive MD.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
310772
Axis %1 drive %2 gain in rough area of valve characteristic is less than or equal to
zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The gradient in the coarse area of the valve characteristic is less than or equal to zero.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
2-920
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents