IEC/IEEE 60255-118 (C37.118) Phasor Measurement
Data Streaming Protocol Configuration PMUCONF
6.1.1
Identification
Function description
Configuration parameters for IEEE
1344 and IEC/IEEE 60255-118.1–2011
protocol
6.1.2
Application
The IED supports the following IEEE synchrophasor standards:
IEEE 1344-1995 (Both measurements and data communication)
IEEE Std IEC/IEEE 60255-118 (C37.118) (Both measurements and data communication)
IEEE Std IEC/IEEE 60255-118 (C37.118) and IEC/IEEE 60255-118 (C37.118).1a-2014
(Measurements)
IEEE Std IEC/IEEE 60255-118 (C37.118) (Data communication)
PMUCONF contains the PMU configuration parameters for both IEC/IEEE 60255-118 (C37.118)
and IEEE 1344 protocols. This means all the required settings and parameters in order to
establish and define a number of TCP and/or UDP connections with one or more PDC clients
(synchrophasor client). This includes port numbers, TCP/UDP IP addresses, and specific
settings for IEC/IEEE 60255-118 (C37.118) as well as IEEE 1344 protocols.
6.1.3
Operation principle
The Figure
IED can support communication with maximum 8 TCP clients and 6 UDP client groups,
simultaneously. Every client can communicate with only one instance of the two available
PMUREPORT function block instances at a time. It means that one client cannot communicate
with both PMUREPORT:1 and PMUREPORT:2 at the same time. However, multiple clients can
communicate with the same instance of PMUREPORT function block at the same time. For TCP
clients, each client can decide to communicate with an existing instance of PMUREPORT by
knowing the corresponding PMU ID for that PMUREPORT instance. Whereas, for UDP clients,
the PMUREPORT instance for each UDP channel is defined by the user in the PMU and the client
has to know the PMU ID corresponding to that instance in order to be able to communicate.
More information is available in the sections
guidance for the use of
Bay control REC670
Application manual
Wide area measurement system
33
demonstrates the communication configuration diagram. As can be seen, the
UDP.
© Copyright 2017 Hitachi Power Grids. All rights reserved
IEC 61850
IEC 60617
identification
identification
PMUCONF
-
Short guidance for the use of TCP
Section 6
Wide area measurement system
GUID-747C6AD7-E6A1-466E-92D1-68865681F92F v2
GUID-1E140EA0-D198-443A-B445-47CEFD2E6134 v2
ANSI/IEEE C37.2
device number
-
GUID-33694C62-A109-4D8F-9063-CEFA5D0E78BC v5
GUID-2608FBC4-9036-476A-942B-13452019BC11 v2
and
Short
93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion rec670

Table of Contents