$ cp /usr/pcs/newconfig/d.x11start ./.x11start
$ chmod u+rwx .x11start
If you use HP 700/X or 700/RX X stations with the HP 4062UX/F system, You must also
perform the following customization for each account. For details, see
Administrator's Guide
If telnet is used to start the X clients on the X stations:
1. Execute the following commands to set the environment variable DISPLAY:
For Bourne shell (sh) or Korn shell (ksh):
$ DISPLAY=
$ export DISPLAY
For C shell (csh):
% setenv DISPLAY
Note that the
hostname
2. Copy a template le for starting up the X Terminal as follows:
$ cd
$ mkdir bin
$ cp /usr/lib/X11/700X/examples/x11start.700x bin/x11start.700x
3. Change the permission of x11start.700x le as follows:
$ chmod u+rwx bin/x11start.700x
4. Modify the x11start.700x le for your environment. You can use VI(1) editor to modify
this le.
a. Add one of the following command lines for your X Terminal:
For color CRT:
### For Color CRT
/usr/bin/X11/xinitcolormap -c 16 /etc/newconfig/rmb/xrmbcolormap
For gray scale CRT:
### For Gray Scale CRT
/usr/bin/X11/xinitcolormap -c 16 /etc/newconfig/rmb/xrmbgraymap
For color CRT with BASIC Plus (greater than 4 planes)
### For Color CRT with BASIC Plus (greater than 4 planes)
/usr/bin/X11/xinitcolormap -f /usr/lib/rmb/PLUS/bplus_colormap
For color CRT with BASIC Plus (4 planes)
### For Color CRT with BASIC Plus (4 planes)
/usr/bin/X11/xinitcolormap -f /usr/lib/rmb/PLUS/bplus_cmap.4
See BASIC Plus manual for creating bplus cmap.4 le.
Note that the shell scripts above must be placed after the error logging procedure as
in the following example:
.
hostname
:0
hostname
:0
is the host name of your X stations.