START ERROR 450 : Fatal error in pcsstart command.

The following error message is displayed:
Location = Obtain_session_key_file()
Function = create()
Parameter = /usr/pcs/session/pcs_
Permission denied
Possible Cause
The owner, group, or permission of
/usr/pcs/bin/pcsstart is incorrect.
The following error message is displayed at a diskless cnode:
Location = Open_hpib()
Function = open()
Parameter = /dev/rmb/hpib27
No such device
or
Location = Open_hpib()
Function = open()
Parameter = /dev/rmb/hpib27
File table overflow
Possible Cause
The kernel for the diskless cnode is not
sucient. The device drivers
are not in the kernel, or
98624
is set to 1.

pcsstart:Error in SYSCONFIG: Invalid select code 29

The following error message is displayed:
pcsstart error 326
pcsstart: fatal error
Location = Open_hpib()
Function = iopen()
Parameter = 27
xxxx
Its owner and group are \root". The permission of
pcsstart must be
commands to change them:
# chown root /usr/pcs/bin/pcsstart
# chgrp root /usr/pcs/bin/pcsstart
# chmod 6555 /usr/pcs/bin/pcsstart
Check the kernel con guration using
and
/usr/lib/rmb/rmbd le command. See
hpib
ndilbuffer
and Maintaining the BASIC/UX System
Chapter 5.
Installation Problems You May Encounter C-3
Solution
. Use the following
-r-sr-sr-x
Solution
Installing
and