Notes on Changing the Burst Length (SH7750R Only): In the SH7750R, when synchronous
DRAM is connected with a 32-bit memory bus, the burst length can be selected as either 4 or 8 by
the setting of the SDBL bit of the BCR3 register. For more details, see the description of the
BCR3 register.
• Burst Read
Figure 13.43 is the timing chart of a burst-read operation with a burst length of 4. Following
the Tr cycle, during which an ACTV command is output, a READ command is issued during
cycle Tc1, and a READA command is issued four cycles later. During the Td1 to Td8 cycles,
read data are accepted on the rising edges of the external command clock (CKIO). Tpc is the
cycle used to wait for the auto-precharging, which is triggered by the READA command, to be
completed in the synchronous DRAM. During this cycle, a new command for accessing the
same bank cannot be issued. In this LSI, the number of Tpc cycles is determined by the setting
of the TPC2 to TPC0 bits of MCR, and no command that operates on the synchronous DRAM
may be issued during these cycles.
Tr
Trw
CKIO
Bank
Row
Precharge-sel
Row
Address
Row
RD/
DQMn
D31–D0 (read)
CKE
DACKn
(SA: IO ← memory)
Note: For DACKn, an example is shown where CHCRn.AL (access level) = 0 for the DMAC.
Figure 13.43 Basic Timing of Synchronous DRAM Burst Read (Burst Length = 4)
Rev. 6.0, 07/02, page 438 of 986
Tc1
Tc2
Tc3
Tc4/Td1
H/L
c1
Td3
Td4
Td2
Td5
H/L
c5
c1
c2
c3
c4
Td8
Tpc
Td6
Td7
c5
c6
c7
c8