258 Actual signals and parameters
All parameters
No.
Name/Value
3104 AR
OVERCURRE
NT
DISABLE
ENABLE
3105 AR
OVERVOLTAG
E
DISABLE
ENABLE
3106 AR
UNDERVOLTA
GE
DISABLE
ENABLE
3107 AR AI<MIN
DISABLE
ENABLE
3108 AR EXTERNAL
FLT
DISABLE
ENABLE
Description
Activates/deactivates the automatic reset for the
overcurrent fault. Automatically resets fault
OVERCURRENT
(0001) after the delay set by parameter
3103 DELAY
TIME.
Inactive
Active
Activates/deactivates the automatic reset for the
intermediate link overvoltage fault. Automatically resets fault
DC OVERVOLT
(0002) after the delay set by parameter
3103 DELAY
TIME.
Inactive
Active
Activates/deactivates the automatic reset for the
intermediate link undervoltage fault. Automatically resets
fault
DC UNDERVOLT
parameter
3103 DELAY
Inactive
Active
Activates/deactivates the automatic reset for AI<MIN
(analog input signal under the allowed minimum level) faults
AI1 LOSS
(0007) and
resets the fault after the delay set by parameter
DELAY
TIME.
Inactive
Active
WARNING! The drive may restart even after a long
stop if the analog input signal is restored. Ensure that
the use of this feature will not cause danger.
Activates/deactivates the automatic reset for faults
FAULT 1
(0014) and
resets the fault after the delay set by parameter
DELAY
TIME.
Inactive
Active
(0006) after the delay set by
TIME.
AI2 LOSS
(0008). Automatically
EXT FAULT 2
(0015). Automatically
Def/FbEq
DISABLE
0
1
DISABLE
0
1
DISABLE
0
1
DISABLE
3103
0
1
EXT
DISABLE
3103
0
1