ABB ACS355 series User Manual page 364

Hide thumbs Also See for ACS355 series:
Table of Contents

Advertisement

364 Fault tracing
CODE FAULT
0101
SERF CORRUPT
(FF55)
0307
bit 14
0103
SERF MACRO
(FF55)
0307
bit 14
0201
DSP T1
OVERLOAD
(6100)
0307
bit 13
0202
DSP T2
OVERLOAD
(6100)
0307
bit 13
0203
DSP T3
OVERLOAD
(6100)
0307
bit 13
0204
DSP STACK
ERROR
(6100)
0307
bit 12
0206
CB ID ERROR
(5000)
0307
bit 11
1000
PAR HZRPM
(6320)
0307
bit 15
1003
PAR AI SCALE
(6320)
0307
bit 15
CAUSE
Drive internal error.
Drive internal error.
Drive internal error.
Incorrect
speed/frequency limit
parameter setting
Incorrect analog input AI
signal scaling
WHAT TO DO
Replace the drive.
If fieldbus is in use, check the
communication, settings and contacts.
Write down fault code and contact
your local ABB representative.
Replace the drive.
Check parameter settings. Check that
following applies:
2001 MINIMUM SPEED
2002 MAXIMUM SPEED
2007 MINIMUM FREQ
2008 MAXIMUM FREQ
2001 MINIMUM SPEED
9908 MOTOR NOM
2002 MAXIMUM SPEED
9908 MOTOR NOM
2007 MINIMUM FREQ
9907 MOTOR NOM FREQ
2008 MAXIMUM FREQ
9907 MOTOR NOM FREQ
within range.
Check parameter group
INPUTS
settings. Check that following
applies:
1301 MINIMUM AI1
1302 MAXIMUM AI1
1304 MINIMUM AI2
1305 MAXIMUM
AI2.
<
<
/
SPEED,
/
SPEED,
/
and
/
are
13 ANALOG
<
<

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents