11411
Meaning:
Special cases, errors,...
11415
MD number
Default value: 0x8
Change becomes effective after: POWER ON
Data type: DWORD
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MN_ENABLE_ALARM_MASK
Screen form to generate alarms, which are normally suppressed.
Bit set: Alarms of this alarm group are output.
Bit not set: Alarms of this alarm group are not output.
Bit hex. Value, significance
=====================================================================
0: 0x1 Alarms are output, which have as alarm response SHOWALARMAUTO.
1: 0x2 Alarms are output, which have as alarm response SHOWWARNING.
2: 0x4 Alarm 22280 "Thread power-up path too short" is output.
3: 0x8 Alarms, which are triggered by the NCU LINK MODULE, are switched-in.
4: 0x10 Alarm 10883 "Chamfer or rounding must be shortened" permitted.
5: 0x20 Alarm 20096 "Brake test interrupted" is output.
6: 0x40 Alarm 16956 "Program cannot be started because of global start inhibit" is output.
Alarm 14005 "Program cannot be started because of program-specific start inhibit" is output.
Alarm can only be switched-in in the RESET channel state, in all other channel states, it is
output without any associated conditions.
7: 0x80 Alarm 16957 "Stop-delay range is suppressed" is output.
8: 0x100 Alarm 1011 Fine coding 150019 or 150020 "Incorrect axis number in the LINK"
9: 0x200 Alarm 22033 Diagnostics 1 to 6 for "Track synchronous operation" (couplings)
10: 0x400 alarm 15122 "PowerOn after power fail: %1 data were restored, of which %2 ma‐
chine data, %3 error" is output.
11: 0x800 Alarms 10722, 10723, 10732 or 10733 are output instead of alarms 10720, 10721,
10730 or 10731.
12: 0x1000 Alarm 22033 Diagnostics greater than or equal to 7 for "Track synchronous oper‐
ation" (couplings)
$MN_SUPPRESS_ALARM_MASK_2
Suppress alarm outputs
Min. input limit: -
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
Data descriptions
Max. input limit:-
Unit: -