Siemens SINUMERIK 840D sl Function Manual page 444

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data descriptions
9.2 Parameters for SINAMICS S120
r9725[0...2]
SI Motion, diagnostics STOP F
Displays the message value that resulted in a STOP F on the drive.
Value = 0: STOP F was signaled from the Control Unit.
Value = 1 ... 999: Number of the incorrect data for a crosswise data comparison
between the two monitoring channels.
Value >= 1000 additional diagnostic values of the drive.
For index 1:
Displays the value of the Control Unit, which resulted in the STOP F.
For index 2:
Displays the value of the second channel, which resulted in the STOP F.
Note:
The significance of the individual values is described in Alarm 27001 of the higher-
level control.
[0] = message value for a crosswise data comparison
[1] = Control Unit crosswise data comparison actual value
[2] = Component crosswise data comparison actual value
See also: C01711
Unit:
Default value:
-
-
p9726
SI Motion, user agreement, select/deselect
Setting to select/deselect the user agreement
0: [00 hex] deselect user agreement
172: [AC hex] select user agreement
See also: r9727
Unit:
Default value:
-
0000 hex
r9727
SI Motion, internal drive user agreement
Displays the internal status of the user agreement
Value = 0: User agreement is not set
Value = AC hex: User agreement is set
See also: p9726
Unit:
Default value:
-
-
444
Minimum value:
Maximum value:
-
-
Minimum value:
Maximum value:
0000 hex
00AC hex
Minimum value:
Maximum value:
-
-
Checksum:
Protection level:
No
3
Data type:
Effectiveness:
Unsigned32
-
Checksum:
Protection level:
No
3
Data type:
Effectiveness:
Integer16
Immediately
Checksum:
Protection level:
No
3
Data type:
Effectiveness:
Integer16
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Safety Integrated

Advertisement

Table of Contents
loading

Table of Contents