Siemens SINUMERIK 840D sl Function Manual page 338

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data descriptions
9.1 Machine data for SINUMERIK 840D sl
13317
MD number
Default value 0H
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13318
MD number
Default value 0H
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
338
$MN_SAFE_GLOB_PREV_CONFIG[0...10]
Data of the previous safety configuration
Min. input limit: 0H
Buffer memory to save previous safety configuration data
Index 0: Status flag bit of the change history
Index 1: Previous value, option data
Index 2: previous value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECK‐
SUM[0]
Index 3: Last value, option data before loading default data
Index 4: last value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECKSUM[0]
before loading standard data
Index 5: previous value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECK‐
SUM[1]
Index 6: last value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECKSUM[1]
before loading standard data
Index 7: previous value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECK‐
SUM[2]
Index 8: last value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECKSUM[2]
before loading standard data
Index 9: previous value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECK‐
SUM[3]
Index 10: last value reference checksum MD13319 $MN_SAFE_GLOB_DES_CHECKSUM[3]
before loading standard data
$MN_SAFE_GLOB_ACT_CHECKSUM[0...3]
Actual checksum NCK
Min. input limit: 0H
Display data:
The actual checksum - calculated after POWER ON or a RESET - over the actual values of
safety-related machine data is entered here.
Assignment of the field indices:
Index 0: General safety parameterization, parameterization of the SPL I/O coupling
Index 1: SPL user data
Index 2: Enable I/O connection (PROFIsafe and F_SEND/F_RECV)
Index 3: PROFIsafe parameters from the S7 configuring
Protection level: 7/2
Protection level: 7/-
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Max. input limit: FFFFFFFFH
Unit: -
Max. input limit: FFFFFFFFH
Unit: -
Safety Integrated

Advertisement

Table of Contents
loading

Table of Contents