11604
Data type: DWORD
Meaning:
corresponds with ...
Special cases, errors,...
13300
MD number
Default value: 0xFFFFFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13301
MD number
Default value: FFFFFFFFH
Change becomes effective after: POWER ON
Data type: DWORD
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MN_ASUP_START_PRIO_LEVEL
This machine data specifies from which ASUB priority the machine data $MN_AS‐
UP_START_MASK is to be applied. MD ASUP_START_MASK is applied from the level speci‐
fied here up to the highest ASUB priority level 1.
MD11602 $MN_ASUP_START_MASK
$MN_PROFISAFE_IN_FILTER[0...47]
F-net data filter IN
Min. input limit: -
Filter between F-net data and $A_INSE variables
This machine data is used to define which bits are transferred from the F-net data interface
of the PROFIsafe module into the NCK for further processing.
The filtered F-net data bits are pushed together inside the NCK to form a bit array without any
gaps (consecutive bit array).
Using machine data MD10388 $MN_PROFISAFE_IN_ASSIGN[n] it is then defined in which
$A_INSE variables the filtered F-net data bits should be transferred.
Example:
Note: For reasons of simplicity, only 16 bits are taken into consideration.
Parameterization:
$MN_PROFISAFE_IN_FILTER = 1010100101000100
$MN_PROFISAFE_IN_ASSIGN = 011006
n = 16 11
6
|x|x|x|x|x|1|1|1|0|0|1|x|x|x|x|x|
$A_INSE[n], x = not relevant
|0|0|0|0|0|0|0|0|0|0|1|1|1|0|0|1|
NCK-internal F-net data image
|1|0|1|0|1|0|0|1|0|1|0|0|0|1|0|0|
$MN_PROFISAFE_IN_FILTER
|1|0|1|0|1|0|0|0|0|0|0|0|0|1|0|0|
example of a value available at the F-net data interface of the PROFIsafe module
$MN_PROFISAFE_OUT_FILTER[0...47]
F-net data filter OUT
Min. input limit: 0
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
1
Protection level: 7/2
Data descriptions
Max. input limit: -
Unit: -
Max. input limit: FFFFFFFFH
Unit: -