Siemens SINUMERIK 840D sl Function Manual page 424

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data descriptions
9.2 Parameters for SINAMICS S120
p9547
SI Motion SSM (SGA n < n
Sets the speed hysteresis for the SSM feedback signal to detect standstill (n < n
See also: C01711
The velocity hysteresis is only effective when the function has been enabled
(p9501.16 = 1).
Unit:
Default value:
mm/min, rpm
10.0000
p9548
SI Motion SBR actual speed tolerance (Control Unit)
Sets the speed tolerance for the safe monitoring of the acceleration (SAM) function
See also: C01706
Unit:
Default value:
mm/min, rpm
300
p9549
SI Motion slip velocity tolerance (Control Unit)
Sets the velocity tolerance, which is applied for a 2-encoder system in a crosswise
comparison between the two monitoring channels.
See also p9501, p9542
If the actual value synchronization is not enabled (p9501 3 = 0), then the value
parameterized in p9542 is used as tolerance in the crosswise data comparison.
Unit:
Default value:
mm/min, rpm
6
p9550
SI Motion SGE changeover tolerance time (Control Unit)
Sets the tolerance time to change over the safety-related inputs (SGE)
Unit:
Default value:
ms
500
p9551
SI Motion SLS (SG) switchover / SOS (SBH) delay time (Control Unit)
Sets the delay time for the SLS changeover and for the activation of SOS for the
functions "Safely-Limited Speed" (SLS) and "Safe Operating Stop" (SOS).
At the transition from a higher to a lower Safely-Limited Speed stage and when
activating a Safe Operating Stop (SOS), the "old" speed level remains active for
this delay time.
This delay still applies even when SLS or SOS is activated from the non-safety
mode.
The set time is internally rounded off to an integer multiple of the monitoring clock
cycle (p9500/p9300).
Unit:
Default value:
ms
100
424
) speed hysteresis (CU)
x
Minimum value:
Maximum value:
0.0010
500.0000
Minimum value:
Maximum value:
0
120 000
Minimum value:
Maximum value:
0
6000
Minimum value:
Maximum value:
0
10 000
Minimum value:
Maximum value:
0
600000
).
Checksum:
Protection level:
x
Yes
3
Data type:
Effectiveness:
FloatingPoint32
POWER ON
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
Floating Point32
POWER ON
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
Floating Point32
POWER ON
Checksum:
Protection level:
Yes
4
Data type:
Effectiveness:
FloatingPoint32
POWER ON
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
Floating Point32
POWER ON
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Safety Integrated