Data descriptions
9.2 Parameters for SINAMICS S120
p10230[0...5]
SI Motion SBT control word
Sets the signal sources for the Safe Brake Test control word.
This parameter is only applicable for "SBT via BICO" (p10203 = 1).
[0] = select brake test
[1] = start brake test
[2] = select brake
[3] = test torque select sign
[4] = select test sequence
[5] = external brake status
Note
For BI: p10230[0]:
0/1 signal: Select the brake test.
0 signal: inactive.
For BI: p10230[1]:
0/1 signal: Start brake test.
For BI: p10230[2]:
1 signal: Select brake 2.
0 signal: Select brake 1.
For BI: p10230[3]:
1 signal: select negative test torque.
0 signal: select positive test torque.
For BI: p10230[4]:
1 signal: Select test sequence 2.
0 signal: select test sequence 1.
For BI: p10230[5]:
1 signal: External brake closed.
0 signal: External brake open.
Unit:
Default value:
-
0
468
Minimum value:
Maximum value:
-
-
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
Unsigned32/Bina‐
POWER ON
ry
Function Manual, 12/2017, 6FC5397-4BP40-6BA1