F01611
SI P1 (CU): Defect in a monitoring channel
6064: Target address and PROFIsafe address differ (F_Dest_Add).
6065: Target address invalid (F_Dest_Add).
6066: Source address invalid (F_Source_Add).
6067: Watchdog time value invalid (F_WD_Time).
6068: Incorrect SIL level (F_SIL).
6069: Incorrect F-CRC length (F_CRC_Length).
6070: Incorrect F parameter version (F_Par_Version).
6071: CRC error for the F parameters (CRC1). The transferred CRC value of the F parameters does not
match the value calculated in the PROFIsafe driver.
6072: F parameterization is inconsistent.
6165: When receiving the PROFIsafe telegram, a communication error was detected. The fault can also
occur, if after switching off and switching on the Control Unit - or after inserting the PROFIBUS-/PROFINET
cable - an inconsistent or out of date PROFIsafe telegram was received.
6166: When receiving the PROFIsafe telegram, a time monitoring error (watchdog) was detected.
Remedy
For fault value = 1 to 5 and 7 to 999:
Check the crosswise compared data that resulted in a STOP F.
Carry out a POWER ON (power off/on) for all components.
Upgrade the Motor Module software.
Upgrade the Control Unit software.
For fault value = 6:
Carry out a POWER ON (power off/on) for all components.
Upgrade the hydraulic module software.
Upgrade the Control Unit software.
For fault value = 1000:
Check the EP terminal at the Hydraulic Module (contact problems).
PROFIsafe: Resolve contact problem/faults at the PROFIBUS master/ PROFINET controller.
For fault value = 1001, 1002:
Carry out a POWER ON (power off/on) for all components.
Upgrade the hydraulic module software.
Upgrade the Control Unit software.
For fault value = 1900, 1901, 1902:
Carry out a POWER ON (power off/on) for all components.
Upgrade the Control Unit software.
Replace the Control Unit.
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
11.3 Safety messages for SINAMICS S120
Diagnostics
697