Siemens SINUMERIK 840D sl Function Manual page 357

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

36919
MD number
Default value: 11
Change becomes effective after: POWER ON
Data type: BYTE
Meaning:
corresponds with ...
36920
MD number
Default value: 10.0
Change becomes effective after: POWER ON
Data type: DOUBLE
Meaning:
corresponds with ...
36921
MD number
Default value: 1
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
36922
MD number
Default value: 1
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MA_SAFE_ENC_PULSE_SHIFT
Shift factor of the encoder multiplication
Min. input limit: 2
Shift factor of the multiplication (resolution) of the encoder that is used for the Safety Integrated
monitoring functions in the NCK. The encoder value must be divided by 2 so many times in
order to obtain the number of encoder pulses. A shift factor of 11 corresponds to an encoder
multiplication by a factor of 2048. If the drive provides this information (r0979[3,13,23]), then
this MD is automatically internally assigned a value after the drive has run up. If the value
changes then Alarm 27036 is output.
$MA_SAFE_ENC_GEAR_PITCH
Leadscrew pitch
Min. input limit: 0.1
Gear ratio of the gearbox (gear) between the encoder and load for a linear axis with rotary
encoder.
$MA_SAFE_ENC_GEAR_DENOM[0...7]
Denominator, gearbox ratio encoder/load
Min. input limit: 1
Denominator of the gear between encoder and load, i.e. the denominator of the fraction num‐
ber of encoder revolutions / number of load revolutions
n = 0, 1, ... ,7 stand for gearbox stages 1, 2, ... 8
The actual value is selected using safety-related input signals (SGE).
MD36922 $MA_SAFE_ENC_GEAR_NUMERA[n]
$MA_SAFE_ENC_GEAR_NUMERA[0...7]
Numerator, gearbox ratio encoder/load
Min. input limit: 1
Numerator of the gear between encoder and load, i.e. the numerator of the fraction number
of encoder revolutions / number of load revolutions
n = 0, 1, ... 7 stand for gearbox stage 1, 2, ... 8
The actual value is selected using safety-related input signals (SGE).
MD36921 $MA_SAFE_ENC_GEAR_DENOM[n]
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/-
Protection level: 7/2
Protection level: 7/2
Protection level: 7/2
Data descriptions
Max. input limit: 18
Unit: -
Max. input limit: 10000
Unit: mm
Max. input limit: 2147000000
Unit: -
Max. input limit: 2147000000
Unit: -
357

Advertisement

Table of Contents
loading

Table of Contents