When UVDX files are used in Expert, only the DO data contained in the file is used. Any
included component information is evaluated only by Topo.
Note
For DO manipulations using a comparison topology, user-specified topology, or DO list
When changing the DO number, the assigned PS file is renamed and parameters "p101" and
"p978" of the higher-level CU are adapted.
The DO name is entered in parameter "p199" of the relevant DO, and the DO variable name
in parameter "p9489".
BICOs are not adapted automatically. This should be noted particularly for the Line Module.
Note
Conflicts in the case of identical names
Conflicts between DO variables with the same name with regard to type, number or name,
result in errors.
Note
The TM31 Terminal Module is not supported by CNC SW 4.4 SP1 with Create MyConfig.
Dialog scripts
In the "Dialog scripts" property, "Scripts" entry, click the
dialog. Here you can edit scripts that are to be executed at selectable times during package
execution.
You can find detailed information on the dialog scripts in the section with the same name
"Dialog scripts (Page 145)".
You can find examples for the dialog scripts for the SINAMICS topology in "Examples of scripts
in dialog pages (Page 149)".
4.4.2.29

SINAMICS topology (package execution)

The "SINAMICS topology" dialog specifies how and which user data must be provided for the
SINAMICS topology in the control.
The dialog checks the Actual topology with the Reference topology. Drive objects for non-
existent modules can be created here.
This dialog corresponds to the "System configuration" dialog.