System Variables For The Finish Dialog; Enumerations For Dialogs - Siemens SINUMERIK 840D sl Operating Manual

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Expert
4.8 Reference list, system variables
4.8.3.18

System variables for the Finish dialog

Table 4-57
"Finish" dialog - PackageEnd (Dialog ID)
System variables
Type
Up.$Dialog.PackageEnd.
Activated
BOOL
ProcessMode
ProcessMode enumera‐
tion (Page 382)
InteractLevel
InteractLevel enumera‐
tion (Page 383)
LogDir
STRING
LogName
See also
End (configuration) (Page 223)
4.8.3.19

Enumerations for dialogs

Enumerations
The enumerations are marked with the icon
icon
Enumeration processing modes - ProcessMode
Range
Enumeration
Processing modes enumeration - ProcessMode
Up.$Dialog.ProcessModes.
AUTOMATIC
MANUAL
PROGRESS
382
Change effective until Description
Last script before dia‐
log
.
Type
Enumerator value
Activating the dialog processing
Processing mode enumeration
Message level enumeration
Path to storage location of the
logbook.
Logbook file name.
and the elements of the enumerations with the
Change effective
Description
readOnly
Automatic editing mode
Manual editing mode
Editing mode progress
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Example
false / true
Up.
$Dialog.ProcessModes.MA
NUAL
Up.
$Dialog.InteractLevels.
ALL
"D:\Log"
"CMC_Package_Log"