Create MyConfig - Expert
4.6 Script language
NC data channel assignment within the NC [C1] to [C10] or CHANDATA (1) to CHANDATA
(10) for NC channels 1 to 10.
Examples
Display data
Syntax
BD[<section>].<BD
variable>
Drive data
Syntax
PS[B<bNr>_S<sNr>_PS<psNr>].<drvD
ata>
4.6.5
Area data
Area data - $MN_?, ... , $MD_?, p?, $MM_?, ...
All variables/identifiers without the package prefix Up. are interpreted as area data. This
includes, for example, machine data, setting data, option data, tool data, drive data, display
data, and user data.
The area data can be written on the left side of an assignment and be read on the right side
of an assignment.
282
[B3_S3_PS3]
p1082[1] = 9000
[SL]
$MM_FIRST_LANGUAGE = 1
Description
Value of the "BD-variable" display machine data item from section
"section".
Values for "section":
● SL for SINUMERIK Operate
If the data is not found, null is returned.
Example:
BD[SL].$MM_TECHNOLOGY
; SINAMICS drive data
; Maximum speed
; SINUMERIK Operate display data
Description
Value of the SINAMICS drive parameter "drvData" of the
specified section:
● Bus with the bus number "bNr"
● Slave with the slave number "sNr"
● Drive object with the number "psNr"
Values from 1 to 99 are valid for "psNr".
Example:
PS[B3_S3_PS1].p105
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE