Create MyConfig - Expert
4.14 SINAMICS device configuration
4.14.3

Drive data generation via "automatic configuration"

Basic procedure
The "automatic configuration" via SINUMERIK Operate or via CMC uses the same functions
internally. In both cases, the SINAMICS determines its actual topology and saves it as target
topology (p9903). This also includes the creation of drive objects (DOs) and their assignment
in a folder structure according to bus number and slave number. Each DO is represented as
a PS file either in ACX or ASCII format (*.TEA). The file PS000000 is used for the consistence
monitoring and the file PS000099 contains configuration data of the internal PROFIBUS. This
structure can be saved as drive archive and imported later.
Figure 4-151
SINAMICS specifies for the "Automatic configuration" DO names, DO numbers, component
names, component numbers, etc., and acquires component properties such as article number,
component category and component type. The parameters for the DOs are read out of the
components, calculated or assigned with factory settings.
The complete data is backed up in the drive data archive.
4.14.4

Drive data generation via "user-specified topology"

Basic procedure
If the SINAMICS device configuration is made with the "User-specified topology," the
SINAMICS is assigned a SINAMICS offline topology package corresponding to the maximum
configuration of the machine in the form of a user-specified topology file (*.utz) from the CMC
package. In other words, components, such as DQI/SMI motors, still may be missing because
commissioning has been performed step by step.
In addition to the topology, the user-specified topology file also specifies the DO names, DO
numbers, component names and component numbers as well as component properties such
as article number and component type. The structure with generalized drive data is also
specified.
434
Drive data storage
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo