Supplementary Conditions For The Use Of Script Libraries; Special Functions/Procedures; Prepare - Siemens SINUMERIK 840D sl Operating Manual

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Figure 4-119
"Insert script" context menu
4.6.18.4

Supplementary conditions for the use of script libraries

When using script libraries, the supplementary condition that the name of a procedure and the
name of a function must only be defined once applies. If you define a procedure or function
several times, this results in an error in the verification run.
However, a procedure and a function with the same name are permitted.
4.6.19

Special functions/procedures

Special functions and special procedures are elements of the CMC script language that are
only used in very special cases when a problem cannot be resolved in the usual way.
4.6.19.1

Prepare

Prepare("<data>", "<value>")
The Prepare() function allows the pre-assignment of defined machine data, which is set by
the package at a later point in time. This point in time depends on machine data and is usually
not achieved via an event script.
The specified machine data <data> is described directly in the control with the specified value
<value>.