Figure 4-119
"Insert script" context menu
4.6.18.4
Supplementary conditions for the use of script libraries
When using script libraries, the supplementary condition that the name of a procedure and the
name of a function must only be defined once applies. If you define a procedure or function
several times, this results in an error in the verification run.
However, a procedure and a function with the same name are permitted.
4.6.19
Special functions/procedures
Special functions and special procedures are elements of the CMC script language that are
only used in very special cases when a problem cannot be resolved in the usual way.
4.6.19.1
Prepare
Prepare("<data>", "<value>")
The Prepare() function allows the pre-assignment of defined machine data, which is set by
the package at a later point in time. This point in time depends on machine data and is usually
not achieved via an event script.
The specified machine data <data> is described directly in the control with the specified value
<value>.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Create MyConfig - Expert
4.6 Script language
345