NEC NEAX 2000 IVS Command Manual page 232

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

COMMAND CODE
42
KIND OF SYSTEM COUNTER
14
Number of Call Forwards in Mul-
tiple-Call Forwarding
15
Maximum number of calls in
queue in each UCD group for con-
trolling external equipment inter-
face (PN-DK00) or Call Waiting
lamp of Multiline Terminal
16
Maximum number of calls in
queue in each UCD group before
busy tone is provided
Number of times for DID Call
Waiting tone
18
Number of times for Camp-On
tone
Note 1: No "Lockout Alarm Display" function if this data is not assigned.
Note 2: The value in parentheses is the initial data when CM08-216/217=0.
Note 3: When Forced Account Code (with AP01) is utilized, CM42 11/12 data will be the same.
Note 4: This data is effective when the 2nd data of CM08-367 is "0". Default setting is no limitation.
Note 5: This data is effective when the 2nd data of CM08-367 is "0".
TITLE:
SYSTEM COUNTER DATA/PAD DATA/TRUNK RESTRICTION CLASS
CONVERSION
INITIAL
DATA
05
01
No
limitation
None
Note 4
No
limitation
Note 5
ND-45669 (E)
Addendum-001
AUGUST, 1998
SETTING DATA
01
Number of times
05
01
Number of calls in queue
in each UCD group
99
01
Number of calls in queue
in each UCD group be-
99
fore busy tone
01
Number of times
99
01
Number of times
99
CM42
REMARKS
In case of CM08,
367=0.
CHAPTER 3
Page 199
Revision 2.1

Advertisement

Table of Contents
loading

Table of Contents