CME7
COMMAND CODE
E7
1.
FUNCTION:
This command specifies the accessible commands for each Password Level.
2.
PRECAUTION:
None
3.
ASSIGNMENT PROCEDURE:
ST + E7YY + DE +
4.
DATA TABLE:
YY
No.
PASSWORD LEVEL
00
Password Level
01
02
03
04
05
06
10
11
12
13
14
15
16
20
To clear all the Password Level
settings for individual commands
21
To clear all the Password Level
settings for all commands
Note: In case of YY = 20, 21, the data to be set is "1" only.
CHAPTER 3
Page 350
Revision 2.0
[CME7]
Password Level
TITLE:
PASSWORD LEVEL
COMMAND CODE
(2 digits)
0 – 6
XX: 00 – FF
1 – 6
2 – 6
3 – 6
4 – 6
5 – 6
6
0
1
2
3
4
5
6
XX: 00 – FF
XX: 00
ND-45669 (E)
DATA
+ DE +
+ EXE
(1 digit)
COMMAND CODE
(Exclusive of 03, E7, E9)
(Exclusive of 03, E7, E9)
Initial Data
:
SETTING DATA
0:
Allowed
1:
Restricted
1: All Password Levels exclud-
ing Level 7 are restricted from
assignment of designated
command.
1:
All Password Levels exclud-
ing Level 7 are restricted
from assignment of all com-
mands.