COMMAND CODE
E0
1.
FUNCTION:
This command allows the maintenance personnel to reset the system with the CAT.
2.
PRECAUTION:
If the setting data (Month, Day and Time) is different from the current time of the system clock (set by
command 02), any request to initialize the system is not accepted and "DATA ERROR" is displayed.
3.
ASSIGNMENT PROCEDURE:
ST + E0Y + DE +
4.
DATA TABLE:
Y
No.
MEANING
2
System Initialization
5
Desired FP/AP
Initialization
Note: For the Data "MMDDHHMM", enter the Month, Date, and Time (hour and minute) of the time, as shown below.
MM :
Month
(01 (Jan.) – 12 (Dec.))
DD :
Date
(01 – 31)
HH :
Hour
(00 – 24)
MM :
Minute (00 – 59)
[CME0]
Initialization
TITLE:
INITIALIZATION
TYPE OF INITIALIZATION
(2 - 4 digits)
TYPE OF INITIALIZATION
No.
MEANING
2000
MP Reset
00
FP/AP Number 00
15
FP/AP Number 15
ND-45669 (E)
DATA
+ DE +
+ EXE
(8 digits)
SETTING DATA
DATA
MEANING
MM
Current time dis-
DD
played on Multiline
HH
Terminal/SN610
MM
ATTCON
Note
To request the ini-
tialization immedi-
ately.
CME0
RELATED
COMMAND
CM02
CM05
CHAPTER 3
Page 347