CMEA
COMMAND CODE
EA
MAT
EXPLANATION OF SCREEN INFORMATION (Continued)
FAULT RESTORATION
KIND NUMBER
18
19
30
31
32
35
36
2: External Alarm Kind (MJ/MN/-)
Use of External Alarm Kind - Minor (MN), Major (MJ) or external alarm is not provided (-) can be
programmed by CMEA Y=2. The following table shows the standard data set by the 2nd data = 3 of
CMEA Y=2.
FAULT KIND
(1ST)
01
System Initialized
03
The number of stack entries was more than the caution level
04
MP-FP/AP communication failure
08
FP/AP package down
09
Power failure
18
FP/AP package returned to normal condition
19
Power failure returned to normal condition
20
DTI line failure
21
DCH D-channel link connection failure
22
CCH link connection failure
25
The number of lockout stations was more than the predetermind number
(Refer to CM42, 1ST data = 01)
26
DLC card down
30
DTI line returned to normal condition
31
DCH D-channel link connection returned to the normal condition
32
CCH link connection returned to normal condition
35
The number of lockout stations was less than the predetermined number
36
DLC card returned to normal condition
CHAPTER 3
Page 356
Revision 2.0
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
FP/AP package returned to normal condition
Power failure returned to normal condition
DTI line returned to normal condition
DCH D-channel link connection returned to the normal condition
CCH link connection returned to normal condition
The number of lockout stations was less than the predetermined number
DLC card returned to normal condition
ND-45669 (E)
FAULT RESTORATION CONTENT
CONTENT
ALARM KIND
MN ALARM
MN ALARM
MN ALARM
MN ALARM
MN ALARM
--
--
MN ALARM
MN ALARM
MN ALARM
MN ALARM
(Fixed)
--
--
--
--
--
--