INFORMATION FOR DATA PROGRAMMING
(2) When deleting data in any command, enter "CCC" as 2nd data. However, data in the following commands
cannot be deleted.
•
Commands where the initial data (
•
CM29, CM41, CM42, CM60 YY = 30.
4.2 Method of Setting On-Line/Off-Line Mode
(1) For the MP card:
(a) Operation for changing on-line mode to off-line mode:
•
Set SW3 to "2" or "3".
•
Press SW1.
(b) Operation for changing off-line mode to on-line mode:
•
Set SW3 to "0".
•
Press SW1.
For details, refer to the Circuit Card Manual.
(2) For the AP card:
(a) Operation of changing on-line mode to off-line mode:
•
Set SW1 as shown below.
SW1
OFF
4
3
2
1
ON
CHAPTER 2
Page 56
Revision 2.0
) is provided but the initial data (
: POSITION TO BE SET
ND-45669 (E)
) is "NONE".