CMEA
COMMAND CODE
EA
MAT
Y
No.
MEANING
2
Registration of fault
information into Fault
Information Memory
for each fault, and
control of external
alarm
Note 1: Even if the external alarm is set as MN or MJ alarm for system initialized (1st data = 01), no alarm is output
in the case of Power On, Reset key operated, initialization from the MAT/CAT, and initialization by SENS
switch selection. (Fixed for the system.)
Note 2: Even if the external alarm is set as MN or MJ alarm for system initialized (1st data = 01), no alarm is output
in the case of Power On, Reset key operated, initialization from the MAT/CAT, and initialization by SENS
switch selection. (Fixed for the system.)
Note 3: The External Alarm Kind for "the number of lockout stations was more than the predetermined number" is
fixed as MN. In the case of this office data, even if the 2nd data is set to 0/1/2/3, it simply means the fault
information is to be registered into Fault Memory. (External Alarm Kind cannot be changed.)
Note 4: Care needs to be taken when setting DLC card down to 1 or 2. You will set an alarm when you unplug any
set program on the DLC.
Note 5: The External Alarm Kind for "the number of lockout stations was less than the predetermined number" is
fixed to no alarm. In the case of this office data, even if the 2nd data is set to 0/1/2/3, it simply means that
the fault information is to be registered into Fault Memory. (External Alarm Kind cannot be changed.)
CHAPTER 3
Page 354
Revision 2.0
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
1ST DATA
DATA
MEANING
(Fault Kind:
Restoration)
18
FP/AP card returned
to normal condition
19
Power failure returned
to normal condition
30
DTI line returned to
normal condition
31
DCH D-channel link
connection returned to
the normal condition
32
CCH Link connection
returned to normal
condition
35
The number of lock-
out stations restored to
less than the pre-de-
termined number
Note 5
36
DLC card returned to
normal condition
3B
ZT returned to normal
condition
ND-45669 (E)
2ND DATA
DATA
MEANING
See the previous page CM08-450,
0
3
NONE
Initial Data
:
RELATED
COMMAND
451
CM42-01, 50