[Cmb0] Peg Count - NEC NEAX 2000 IVS Command Manual

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

CMB0
COMMAND CODE
B0
MAT
1.
FUNCTION:
This command allows accumulated data of use for maintenance purposes to be read from the system
PEG counter. Data can be cleared after reading.
2.
PRECAUTION:
(1) When the system is reset, the contents in the memories of the PEG counter are all cleared.
(2) This command is included in MAT mode menu "D1" (Peg Count [COM03]).
3.
ASSIGNMENT PROCEDURE:
Y=0
• To clear individual data
ST + B00 + DE +
• To clear all PEG COUNT data
ST + B00 + DE + 999 + DE + CCC + EXE
• To display
ST + B00 + DE +
Y=2
• To set the PEG COUNT measurement start/end time
ST + B02 + DE +
• To display the PEG COUNT measurement Status
ST + B02 + DE + 2 + DE
CHAPTER 3
Page 328
Revision 2.0
[CMB0]
Peg Count
TITLE:
PEG COUNT
TRUNK STATUS DATA
(3 digits)
TRUNK STATUS DATA
(3 digits)
1st DATA
+ DE +
(0/1)
ND-45669 (E)
+ DE + CCC + EXE
+ DE
2nd DATA
+ EXE
(8 digits)

Advertisement