Set Up Warning Message; Set Up Auto Dial (Security Sensor) Using Service Code; Start Security Operation - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program 10-41-01(Index 1): (2) Slot Number connected with 2PGDAD
Program 10-41-02(Index 1): (8) Port Number connected with 2PGDAD
Program 10-41-03(Index 1): (1) Detection cct no. on 2PGDAD where a Sensor is connected to
Program 11-10-47: (615) Warning message setting
Program 11-10-48: (617) Auto Dial Setting for Security Sensor
Program 11-12-62: (716) Security Sensor Reset
Program 11-12-64: (719+1/0) Security Sensor Mode Start/Stop
Program 15-07-01: Set
Program 20-46-01: (1) Sensor mode, on
Program 20-46-02: (1) Internal paging group, 1
Program 20-46-03: (1) External paging group, 1
Program 20-46-04: (1) VRS message number for warning, 1
Program 20-46-05: (1999) Speed dial bin number, 1999
Program 20-46-06: (2) VRS message number for destination answer, 2
Program 20-46-07: (10) Auto Dial Wait Timer, 30 sec
Program 20-46-08: (3) Times of auto repeat dial, 3
Program 20-46-09: (30) Auto dial calling time, 30 sec
Program 20-46-10: (200) Monitored terminal number, 200
Program 20-46-11: (30) Interval of Auto Dial, 30 sec
Program 20-46-12: (1) General purpose relay contact detector circuit 1
Program 20-48-01: (1) Security sensor time pattern, 1
Program 20-55-01: (60 sec, default) Sensor delay timer

Set up Warning message:

1.
Press Speaker and dial 719.
2.
Dial the Security sensor number 1.
3.
Dial the Internal paging group number, 01.
4.
Dial the external paging group number, 1.
5.
Dial the VRS message number for the warning, 001.
6.
After the beep, record message.
7.
Press Speaker to hang up.

Set up Auto Dial (Security Sensor) Using Service Code:

1.
Press Speaker and dial 748.
2.
Dial the Security sensor number (1~8), 1.
3.
Dial the Speed dial bin number to be used, 1999.
4.
Dial the emergency call destination number xxx-xxx and press Hold.
5.
Dial the monitored terminal number, 200.
6.
Dial the VRS message number 002.
7.
After the beep, record message.
8.
Press Speaker to hang up.

Start Security Operation:

1.
Press Speaker and dial 819 + 1. The sensor is enabled using the timer in Program 20-55-01.
*
33 to Function key
1057

Advertisement

Table of Contents