Program
Program Name/Description
Number
Multiline Telephone Basic Data Setup –
15-02-22
Multiple Incoming From Intercom and Trunk
When this option is Disabled, incoming calls to
an extension indicate on any Hotline key for
that extension as solid (busy). When this option
is Enabled, lighting is determined by the setting
of Program 22-01-01 Incoming Call Priority. If
set to trunk (1), the Hotline key lights solid when
a trunk call rings in. If set to intercom (0), the
Hotline key does not light for incoming trunk
calls, but lights solid for intercom calls.
20-06-01
Class of Service for Extensions
Assign a Class of Service to extensions
(1 ~ 15).
20-08-09
Class of Service Options (Outgoing Call
Service) – Hotline/Extension Ringdown
Turn Off or On Hotline (Ringdown). If disabled
in COS, the settings in Program 21-11 below
have no effect.
20-08-19
Class of Service Options (Outgoing Call
Service) – Hotline for SPK
Turn Off or On an extension user ability to press
Speaker to activate hotline or ringdown.
20-11-06
Class of Service Options (Hold/Transfer
Service) – Unscreened Transfer (Ring
Inward Transfer)
Turn Off or On an extension user ability to use
Unscreened Transfer.
20-11-11
Class of Service Options (Hold/Transfer
Service) – Automatic On-Hook Transfer
Turn Off or On an extension user ability to use
Automatic On-Hook Transfer.
20-13-06
Class of Service Options (Supplementary
Service) – Automatic Off-Hook Signaling
(Automatic Override)
Program 20-02-03 and Program 20-13-06 set
the conditions under which a Hotline, Reverse
Voice Over or DSS Console key indicates that
an extension is busy. With condition 1 in the
following chart, the BLF LED is on only when
both extension line appearances are busy. In
conditions 2 ~ 4, the BLF LED is on when one
line appearance is busy.
System Options for Outgoing Calls –
21-01-09
Ringdown Extension Timer (Hotline Start)
A Ringdown extension automatically calls its
programmed destination after this time.
Input Data
0 = Disable
1 = Enable
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 ~ 64800 seconds
566
Default
1
Extension port
101 = Class 15
All other
extension port =
Class 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0
COS 1 ~ 15 = 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 1
Refer to
Extension Busy
Setup Table
below
5 seconds