NEC UNIVERGE SV9100 Features And Specifications page 183

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
20-09-01
Class of Service Options (Incoming Call
Service) – Second Call for DID/DISA/DDI/
DIL/ E&M Override
Turn Off or On an extension ability to receive a
second call from a DID, DISA, DIL, or tie line
caller.
With this option set to 1, the destination
extension must be busy for a second DNIS caller to
ring through. If the destination extension does not
have a trunk or CAP key available for the second
call and a previous call is ringing the extension but
has not yet been answered, the second caller hears
busy regardless of this program setting.
20-09-07
Class of Service Options (Incoming Call
Service) – Call Queuing
Turn Off or On an extension ability to have calls
queued if a call rings the extension when it is
busy.
Program 20-13-06 must be set to 0 (Off) for
this feature to work.
20-13-05
Class of Service Options (Supplementary
Service) – Intercom Off-Hook signaling
Turn Off or On an extension ability to send
off-hook signals.
This setting functions with Programs 20-09-07
and 20-13-06 disabled.
20-13-06
Class of Service Options (Supplementary
Service) – Automatic Off-Hook Signaling
(Automatic Override)
Allow a busy extension user to Manually (0) or
Automatically (1) receive off-hook signals.
This setting is to receive incoming call
signaling information during call queuing.
20-13-35
Class of Service Options (Supplementary
Service) – Block Camp-On
Turn Off or On an extension user ability to block
callers from dialing to camp-on.
Service Tone Timers – Interval of Call
20-18-06
Waiting Tone
Set the time between call waiting tones. This
timer also sets the interval between off-hook
signaling alerts.
System Options for Outgoing Calls – Reset
21-01-18
Dial After Failure of Trunk Access
Enable/Disable an extension user ability to
continue to dial codes or extensions after
receiving Trunk Busy. This must be Enabled for
this feature to work.
Input Data
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 ~ 64800 seconds
0 = Enable (On)
1 = Disable (Off)
183
Default
COS 1 ~ 15 = 1
COS 1 ~ 15 = 1
COS 1 ~ 15 = 1
COS 1 ~ 15 = 1
COS 1 ~ 15 = 0
10
1

Advertisement

Table of Contents
loading

Table of Contents