To Flash The Trunk You Are On - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
COT Initial Data Setup – Hookflash Time
81-10-07
Selection 1
Set the Flash duration (16 ~ 4080ms) for
analog trunk GCD-4COTA circuits in Program
81-10-07.
COT Initial Data Setup – Hookflash Time
81-10-08
Selection 2
Set the open loop disconnect duration
(16 ~ 4080ms) for analog trunk GCD-4COTA
circuits Program 81-10-08.
Operation

To flash the trunk you are on:

From a Multiline Terminal
1.
Press Recall.
From a Single Line Telephone
1.
Hookflash.
2.
Dial
3.
#
Input Data
0 = 20ms
1 = 40ms
2 = 60ms
3 = 80ms
4 = 100ms
5 = 140ms
6 = 160ms
7 = 200ms
8 = 400ms
9 = 600ms
10 = 800ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
0 = 20ms
1 = 40ms
2 = 60ms
3 = 80ms
4 = 100ms
5 = 140ms
6 = 160ms
7 = 200ms
8 = 400ms
9 = 600ms
10 = 800ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
480
Default
9 = 600ms
14 = 3.0 seconds