Program
Program Name/Description
Number
12-07-01
Text Data for Night Mode
Create an original text message which is
displayed on an LCD of multiline terminal in
each Night Mode.
12-08-01
Night Mode Service Range
For each Night Mode Group (01 ~ 32),
determine how many night modes a user
toggles through when the Night Mode key is
pressed.
14-07-01
Trunk Access Map Setup
To allow for Universal Night Answer (UNA)
answering, set up the Trunk Access Maps
(1 ~ 400). For UNA, extension must have
incoming access to trunk ringing the External
Paging speakers.
15-06-01
Trunk Access Map for Extensions
For Universal Night Answer (UNA) answering,
assign Trunk Access Maps (1 ~ 400) to
extensions. Make one entry for each Night
Service mode.
15-07-01
Programmable Function Keys
Assign Night Service function keys (09) to
extensions and set the key for the proper mode
(Day, Night, Rest, etc.). If the additional data is
set to 0, the toggle mode is assigned.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Input Data
Night Mode Service Group
Number:
01 ~ 32
Day/Night Mode: 1 ~ 8
Text Message:
Maximum 12 Characters
(alphabetic or numeric)
Night Mode Service Group
Number:
01 ~ 32
Range: 2 ~ 8
0 = No access
1 = Outgoing access only
2 = Incoming access only
3 = Access only when trunk on
Hold
4 = Outgoing access and access
when trunk on Hold
5 = Incoming access and access
when trunk on Hold
6 = Incoming and Outgoing
access
7 = Incoming access, outgoing
access and access when trunk
on Hold
Trunk Access Maps: 1 ~ 400
Trunk Access Maps: 1 ~ 400
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
*
00 ~
99 (Appearance
Function Code) (Service Code
852 by default)
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
926
Default
Default Text
Messages for
Day/Night
Modes:
Mode 1 = No
Setting
Mode 2 =
<Night>
Mode 3 =
<Midnight>
Mode 4 =
<Rest>
Mode 5 =
<Day2>
Mode 6 =
<Night2>
Mode 7 =
<Midnight2>
Mode 8 =
<Rest2>
2
Access Maps
1 ~ 400 = Trunk
Ports 1 ~ 400
assigned with
option 7 access
(incoming and
outgoing access
and access
when trunk is on
Hold).
1
Extension port
101 = Class 15
All other
extension port =
Class 1

Advertisement