-OR-
2.
Press function key (
20-55-01 expires. The sensor is valid.
-OR-
3.
Security Sensor time pattern 1 starts.
Stop Security Operation:
1.
Press Speaker and dial 819 + 0.
-OR-
2.
Press the red lit function key (
3.
Security Sensor time pattern 1 stops.
When Detect Security Sensor is On:
1.
A Warning message sent to internal page group 1 and external page group 1.
2.
An outgoing call is automatically sent according to setting in speed dial bin 1999.
3.
When destination answers, VRS sends a second message.
4.
Once received, extension 200 can be used for monitoring. To have a two-way conversation, dial
*
.
To Send Warning message:
To send a Warning message, but not as an Emergency call:
Change Program 20-46-05 to no setting.
To Place an Emergency Call:
To send an Emergency call, but not as an Warning message:
Set Programs 20-46-02 and 20-46-03 to 0.
Remote Inspection
<Program>
Program 11-10-49: (619) Auto Dial Setting for Remote
Program 20-45-01: (200) Remote Inspection terminal, 200
Program 20-45-02: (12:00) Ringing start time, 12 o'clock noon
Program 20-45-03: (3) ringing continue time, 3 minutes
Program 20-45-04: (1999) Speed dial bin number, 1999
Program 20-45-05: (1) VRS message number when inspected extension answered, 1
Program 20-45-06: (2) VRS message number when emergency call destination answered, 2 Program 20-
45-07: (3) Times of auto repeat dial, 3
Program 20-45-08: (30) Auto dial calling time, 30 sec
Program 20-45-09: (30) Interval of Auto Dial, 30 sec
Set Up Remote Inspection:
1.
Press Speaker and dial 819.
2.
Dial the Remote Inspection terminal number (1-6).
*
33), the function keys turn red. The key lights after the timer in Program
*
33), the function keys turn off.
1058