Panasonic MICRO-IMAGECHECKER PV310 Use Manual page 129

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

Setting procedure - Changing Accuracy, Detection Max. and Correlation Min.:
1. Highlight "Sequence".
The cursor moves to the "1ST" cell in the "Step" column.
2. Select the phase you want to change and press the ENTER key.
The cursor moves to the cell in the "Acc." column.
3. Highlight the column in which the item you want to change is and press the ENTER key.
Option
Description
Acc
Select one of the accuracies available at this phase.
Det. Max.
Specify the number of templates to be detected at this phase. The
range from 01 to 64 is available. After changing the upper limit of
detection count, press the ENTER key.
Corr. Min.
The range from 0.01 and 1.00 is available. When changing the
lower limit of correlation value, press the ENTER key.
4.
Press the C key.
The cursor advances to the next phase.
5.
After setting "Acc.", " Det. Max." and "Corr. Min." at the entire phases, press the C key.
The cursor moves to the Sequence tab.
121