Data Assignment For Handshake - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

10.1.3 Data Assignment for Handshake

Output of judgment results
If "Handshake" is set to "No", the signals JD01 to 08 signals are output to the terminals D1 to D8.
Judgment results including the last number are output in 8-bit form. But, if the PV310 is in User-Defined mode
and Automatic Switch mode, only the judgment formulas of the executed block and only the Judgment formulas
of block 2 or 3 are output respectively.
1st.
D8
JD08
2nd.
D8
JD16
12th
D8
JD96
Data output of Number of scans, Numeric Calculation
The data of the number of scans and Numeric Calculation are assigned according to the setting value for "Data
Type" as the tables shown below. The data of items that are set not to output are skipped (not output).
Output Data: 8 bits
D8
Bit 7
Output Data: 16 bits
1st.
D8
Bit 7
2nd.
D8
Bit 15
Output Data: 32 bits
1st.
D8
Bit 7
2nd.
D8
Bit 15
3rd.
D8
Bit 23
4th
D8
Bit 31
D7
D6
D5
JD07
JD06
JD05
D7
D6
D5
JD15
JD14
JD13
D7
D6
D5
JD95
JD94
JD93
D7
D6
D5
Bit 6
Bit 5
Bit 4
D7
D6
D5
Bit 6
Bit 5
Bit 4
D7
D6
D5
Bit 14
Bit 13
Bit 12
D7
D6
D5
Bit 6
Bit 5
Bit 4
D7
D6
D5
Bit 14
Bit 13
Bit 12
D7
D6
D5
Bit 22
Bit 21
Bit 20
D7
D6
D5
Bit 30
Bit 29
Bit 28
D4
D3
JD04
JD03
D4
D3
JD12
JD11
D4
D3
JD92
JD91
D4
D3
Bit 3
Bit 2
D4
D3
Bit 3
Bit 2
D4
D3
Bit 11
Bit 10
D4
D3
Bit 3
Bit 2
D4
D3
Bit 11
Bit 10
D4
D3
Bit 19
Bit 18
D4
D3
Bit 27
Bit 26
D2
D1
JD02
JD01
D2
D1
JD10
JD09
D2
D1
JD90
JD89
D2
D1
Bit 1
Bit 0
D2
D1
Bit 1
Bit 0
D2
D1
Bit 9
Bit 8
D2
D1
Bit 1
Bit 0
D2
D1
Bit 9
Bit 8
D2
D1
Bit 17
Bit 16
D2
D1
Bit 25
Bit 24
243