To check the number of the executed block
The number of the executed block is displayed in the information area.
How to set a block number
When you input inspection start signal, START signal or inspection start serial command from the external device,
specify the desired block. The block number can be specified when inspection is executed by using the keypad, too.
How to specify a block number when starting an inspection by I/O input
When you input START signal, control inspection
execution by using I/O ports IN1 and IN2 as the
table shown on the right.
Enter IN1 and IN2 1 ms and more before entering a
START signal.
How to specify a block number when starting an inspection by sending a serial command
When you send a serial command to the PV310
from an external device, issue a special command to
specify a block number as the table shown on the
right.
How to specify a block number when starting an inspection by pressing the A key on the keypad
When you press the A key in RUN mode, a dialog box from which you can select the desired block is
displayed. Only the selected block is executed.
Specified
IN2
block
1
OFF
OFF
2
OFF
3
ON
OFF
Specified
Command
block
1
%S1CR
2
%S2CR
3
%S3CR
IN1
START
ON
+
ON
ON
ON
215