Details Of Commands - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

11.2.6 Details of Commands

Command for Inspection Start (%S)
For either "All" or "Automatic Switch" execution mode
Communication direction
From external device to
PV310
Response
For "User-Defined" execution mode
Communication direction
From external device to
PV310
Response: Normal
Response: Error
Command / Description
% S CR
Output results of inspection and numeric calculation that have been set to output.
See page 260 for output format.
Command/Description
% S
?
CR
?: 1 - 3 (Specify a one-digit block number.)
Outputs the data of Judgment or calculation results in the executed block.
See page 260 for output format.
% U CR
Cause:
The block number specified by the output command is other than 1 to 3.
263

Advertisement

Table of Contents
loading

Table of Contents