Panasonic MICRO-IMAGECHECKER PV310 Use Manual page 287

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

Command format: Fixed Length
Even if "Format" is set to "Fixed Length", more than 5-digit data can be sent using this command.
Communication direction
From external device to PV310
Response: Normal (At the end
of specifying the number of
command digits)
Response: Error 1
Response: Error 2
ERROR signal = "ON"
Error Code: E0179 is
displayed on the screen
To specify the command format (Comma separated/Fixed Length), select "ENVIRONMENT" > "Serial
Communication"> "Command" from the menu bar.
Command / Description
%
N
?
?
Min.
Max. CR
??
01 to 96
Min.
Fixed (12 Digits)
Max.
Fixed (12 Digits)
- 02147483648 to 002147483647: If Unused digits are filled with '0'.
- 02147483648 to 002147483647: If Unused digits are filled with 'Blanks'.
%
N
?
?
Min.
Max. CR
The same command as the sending command from external device to PV310
transmitted.
%
U CR
Cause:
Command in the unspecified form or not provided was received.
Examples:
%C3-02147483648002147483647 CR (any other checker number than 01 to
96 was specified)
%B03-02147483648002147483647 CR (not provided command)
%
Z CR
Causes:
The max. specified by a sending command is smaller than the min. value.
The max. /min. specified by a sending command is not within the available
range.
The max. /min. specified by a sending command is not 12 digits.
Specify the number of Numeric Calculation No. in
2-digit form
- 02147483648 to 002147483647
or
- 02147483648 to 002147483647
279