Re-registering Templates of Smart Matching and Contour Matching (%A)
This command is for re-registering the template for Smart Matching and Contour Matching using the signals from
external device.
Re-registering the Template - Display Area: No
Communication Direction
From external device to
PV310
Response: OK:
Re-registration complete
Response: Error 1
Response: Error 2
ERROR signal = "ON"
Error Code: E0174 is
displayed on the
screen
When a live image is displayed, it is newly re-registered after captured.
When a memory image is displayed, template is registered using the currently displayed memory image
(the last captured image).
The images are discarded when the power turns off unless saving them. To hold the images even if the
power turns off, save the current settings by selecting "SAVE" from the menu bar or by inputting a
command of "%MCR" from the external device.
Command / Description
%
A
?
? CR
??: 01 to 99
(Specify the number of the folders where product types and configuration data are
stored in 2-digit form.)
%
A CR
%
U CR
Cause:
Command in the unspecified form or not provided was received.
Examples:
C
%A9
(any other checker number than 01 - 99 was specified.)
-
R
C
%B01
(not provided command)
-
R
%
Z CR
Causes:
The checker types already saved as the specified numbers are not Smart
Matching or Contour Matching.
Template is not registered using the Smart Matching or Contour Matching checker
already saved as the specified number.
As the image in the re-registration area has no feature, it cannot be registered as a
template.
When re-registration position = Adjusted Position, grouped Position Adjustment (or
Rotation Adjustment) is NG
When re-registration position = Adjusted Position, the position adjusted using
grouped Position Adjustment (or Rotation Adjustment) checker is out of the screen.