Changing Max. /Min. of Numeric Calculation [%N]
This command is for changing the max. and min. values of numeric calculations (01 to 96). The PV310 can change
max. /min. of numeric calculations for the currently selected product type.
Command format: Comma separated
Communication direction
From external device to PV310
Response: Normal (at the end
of changing Max. /Min.
Numeric Calculation)
Response: Error 1
Response: Error 2
ERROR signal = "ON"
Error Code: E0179 is
displayed on the screen
To specify the command format (Comma separated/Fixed Length), select "ENVIRONMENT" > "Serial
Communication"> "Command" from the menu bar.
278
Command / Description
%
N
?
?
,
Min.
??
01 to 96
(Specify the numeric calculation number in 2-digit
form).
Min.
- 2147483648 to 2147483647
Max.
up to 11 digits including a "-" (minus sign)
For example, if Numeric Calculation No.= 1, Min. = -2000, Max.= 500,
the sending command will be %N01, -2000,500 or %N01, -2000,00500
%
N
?
?
,
Min.
The same command as the sending command from external device to PV310
transmitted.
%
U CR
Cause:
Command in the unspecified form or not provided was received.
Examples:
-
%N3, 1000, 25000
specified)
%B03, 1000, 25000
-
%
Z CR
Causes:
The max. specified by a sending command is smaller than the min. value.
The max. /min. specified by a sending command is not within the available
range.
The max. or min. value includes anything except numbers.
E.g.) %N01, __100, __500
,
Max. CR
,
Max. CR
C
(any other checker number than 01 to 99 was
R
C
(not provided command)
R