11.2.5 List of Commands
PV310 provides the following commands:
Type of Command
Commands for inspection start
Commands for reading or
changing the setting data
stored in the PV310
Other
•
About the commands for changing each setting value
The PV310 will lose the images if the power is removed before you save them.
- Smart Matching, Contour Matching - Re-registering templates
- Slice Level: Changing upper/lower limits
- Gray Edge: Changing edge threshold
- Num. Calcu.: Changing the max./min. values
262
Command
To execute inspection
To transmit product type and configuration data in a
Compact Flash memory card to the PV310
Smart Matching, Contour Matching - Re-registering
a template
Slice Level - Reading Min./ Max
Slice Level - Changing Min. / Max.
Gray Edge - Reading threshold of edge
Gray Edge - Changing threshold of edge
Num. Calcu. - Reading Min. /Max.
Num. Calcu. - Changing Min. /Max.
Data Save - Storing the current settings in the PV310
Switching to another product type
Resetting Statistics Data
Changing Display Image
Emulating the Keypad
Reference
page
%S
263
%F
264
%A
265
%L
267
%T
268
%H
270
%G
272
%C
276
%N
278
%M
280
%X
280
%Q
280
%I
281
%K
282