Panasonic MICRO-IMAGECHECKER PV310 Use Manual page 221

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

Outputting inspection results
You can output only the results of the block executed last to the external device. The results of block 1 (JD01-32
and CA01-32) executed first are not output.
To output inspection results to parallel output ports
Execution of block 2
D8
D7
JD39
JD38
Execution of block 3
D8
D7
JD72
JD71
During handshake, the Judgment results in the tables shown above are output first, then the rest of the Judgment
results are output to the ports D1 through D8 in several times.
Output inspection results to RS-232C port (if four Judgment and Numeric Calculation formulas of four
smallest numbers)
Execution of block 2
JD33
JD34
Execution of block 3
JD65
JD66
* The inspection results are output from the top of each block even in Computer Link mode.
To output the results of block 1
In Automatic Switch execution mode, the PV310 executes block 1 whenever executing inspection, but the results
are not output. If you output the result or calculation data of block 1 to an external device, save the formula of
Numeric Calculation or Judgment that you want to output as block 2 or 3.
Example: To output the result of JD01 and calculation data of CA01 of block 1 to an external device
Settings
Judgment
JD33 = JD01
JD65 = JD01
Output results:
When block 2 was executed, the result of JD33 and the calculation data of CA33 are output.
When block 3 was executed, the result of JD65 and the calculation data of CA65 are output.
If you configure the same settings as the table shown above, the result of JD01 and calculation data of CA01 can
be output regardless of the block the PV310 executes.
D6
D5
D4
JD37
JD36
JD35
D6
D5
D4
JD70
JD69
JD68
JD35
JD36
CA33
JD67
JD68
CA65
Numeric Calculation
CA33 = CA01
CA65 = CA01
D3
D2
D1
JD34
JD33
JD32
D3
D2
D1
JD67
JD66
JD65
CA34
CA35
CA36
CA66
CA67
CA68
C
R
C
R
213

Advertisement

Table of Contents
loading

Table of Contents