Data Displaying - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

7.5.2 Data Can Be Displayed in the Data Monitor Table
The data listed below can be referred to the Data Monitor.
Reference Data
Title
Calculation
Result of Numeric
Result
Calculation
Judgment of Numeric
Calculation
Judgment of Judgment
Calculation
Statistics
Product Type

7.5.3 Data Displaying

Result of Numeric Calculation and Judgment of Numeric/Judgment Calculation
To refer the result and judgment of numeric calculation and judgment of judgment calculation, follow the steps
below.
1.
Select "TOOL" > "Calcu. -Stat.-Output" from the menu bar.
The subwindow for calculation, statistics and output setting is
displayed.
2.
Highlight the Data Monitor tab.
The table consisting of 5 columns and 10 rows is
displayed.
3.
Move the cursor to the desired cell.
4.
Choose "Calcu. Result".
The subwindow is displayed.
5.
Select the item you want to refer
The cursor moves to the number right next to the
item you selected.
6.
Specify the number of the quoted item and
press the ENTER key.
The symbol of the selected data appears.
194
No.
Content
-
Titles containing numbers, alphabets and symbols
01 to 96
Calculation result of a Numeric Calculation formula
01 to 96
Judgment result of a Numeric Calculation formula
01 to 96
Judgment result
00
Scan Number
01 to 96
OK Count
NG Count
OK Average
OK Disperse
Max.
Min.
Range
-
The number of current product type

Advertisement

Table of Contents
loading

Table of Contents