Result Output; Setting Procedure; Establishing Communication Between Pv310 And Computer - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

12.3 Result Output

12.3.1 Setting Procedure

If you establish communication via Ethernet, select output destination (Ethernet port) and data to output. Select
"ENVIRONMENT" > "Data output settings" from the menu bar.
Data output settings
Set output destination, output data or output data format.
Item
Option
Output Setting
Not Output / Serial (Per Start) / Computer
Link / Serial (Async.) / Ethernet / CF
Output Data
Number of Scans/Judgment/Numeric
Calculation/Statistics
Output Digits*
1 to 11
Unused Digits*
Comma separated / Filled with '0'
*The format of the output data differs depending on the setting value. Refer to page 260

12.3.2 Establishing Communication between PV310 and Computer

Establish communication between PV310 and a computer using the software that supports for Telnet installed on
the computer. The example of communication using "HyperTerminal" normally provided with Windows* is as
described below.
1.
Start HyperTerminal on the computer.
2.
Type a name (e.g. 'test') for storing communication settings in the box and click OK.
3.
Select "TCP/IP" from the Connect Using menu.
4.
Type the IP address that is already set on the communication destination (PV310) in the Host
Address box and input "8601" in the Port Number box.
Now you completed all the settings required to start Ethernet communication.
Perform inspections on PV310 and check to make sure that proper inspection results are displayed.
Disconnecting Ethernet communication from Telnet
To disconnect Ethernet communication, follow the steps below.
1.
Remove power from the PV310.
2.
Disconnect communication via Telnet.
If disconnecting the communication using Telnet or detaching the Ethernet cable before removing power
from the PV310, the PV310 may fail to recognize the connection with the computer when Telnet reconnects
with the PV310. In such a case, execute multiple inspections by inputting START signal or pressing the A
key on the keypad for proper recognition of the connection.
Windows ® is a registered trade mark of Microsoft Corporation in the United States and other countries.
294
Description
To select an output destination or output method.
Select "Ethernet".
To select output data.
Specify the maximum number of digits to output.
If the digit number of the data is less than the
output digit number you have set, select "Comma
separated" to delete the unused digit of the data or
"Filled with 0 " to treat it as "0".

Advertisement

Table of Contents
loading

Table of Contents