7.5.3 Quoting the Data to the Data Monitor

Calculation Result and Judgement of Numeric/Judgement Calculation
To quote result and judgement of numeric calculation and judgement of judgement calculation, follow the
steps below.
1.
Select "TOOL " > "Calcu. -Stat.-Output" from the menu under.
The subwindow for calculation, statistics and output setting is displayed.
2.
Highlight the Data Monitor tab.
The table with 5 columns and 10 rows is displayed.
3.
Move the cursor to the desired cell.
4.
Choose "Calcu. Result".
The subwindow is displayed.
5.
Select the item you want to quote.
The cursor moves to the number on the right of "Calcu.".
6.
Specify the number of the quoted item and press the ENTER key.
The symbol of the selected data appears.
171