6.17.2 Registering a Base Position
The way of registering the current object as a base position is described below. To register a base
position, perform a test to check if the Areas 1 and 2 detect an edge. When a live image is displayed,
perform the test after importing a new image. When a memory image is displayed, perform the test using
the memory image currently displayed without importing a new image.
Registration Procedure:
1.
Select the "Base Position" tab.
The cursor moves to "Base Setting".
2.
Press the ENTER key
When the dialog message shown above appears, choose "YES" to
continue.
If the edges were correctly detected and the base position was resisted,
the following data appears in the message area.
Judgement: OK
Adj. X: 0.0
Adj. Y: 0.0
If the following message appears, it means that an edge in either Area 1 or Area 2 was not detected.
Check the setting values of areas (positions of start and end points) or the inspection objects.
E0042 Base position cannot be detected.
6.17.3 What To Do If You Faced a Trouble
Judgement result is always NG.
The following causes may be occurred.
• The object cannot be detected
Recheck and reconsider the area size and the detection conditions (including Target, Filter, Width, and
Priority).
• No base position is registered.
The error code "E0049" may be displayed.
Since any base position is not registered, AX40 cannot work properly. Note that if you change area position,
size and shape after registering it, you need to register the base position again.
• Position Adjustment that refers to adjustment amount cannot detect the object.
If Position Adjustment is set to the numbers except "0", the adjustment amount of Position Adjustment or
Rotation Adjustment that is registered to the number is referred. If the Position Adjustment or Rotation
Adjustment checker cannot detect the object, the adjustment amount cannot be referred. Therefore, AX40
does not function properly and outputs "NG" result.